Minimum
    England

    Additional flue terminal separation rules

    300 mm

    Beyond standard table distances, all flue terminals must maintain a minimum 300mm clearance from any combustible material, such as window frames

    Beyond standard table distances, all flue terminals must maintain a minimum 300mm clearance from any combustible material, such as window frames. If a heat shield is installed, it should be at least 750mm wide to protect combustible materials. Terminals for vaporising burners require a minimum 2.3m horizontal separation from the roof, and vertical balanced flue outlets must follow manufacturer instructions.

    Basis in regulation

    How to check it on site

    Confirm all terminals are at least 300mm from combustible window frames, and verify heat shield dimensions if present.

    Common failure

    Terminal placement too close to combustible window or door frames, ignoring the absolute minimum clearance requirement.