    AVCL jointing requirements

    100 mm

    Joints in air and vapour control membranes must be adequately lapped, typically with a minimum overlap of 100mm, to ensure continuity of the membrane

    Every figure for this topic is on one page: Roof void ventilation, access and fire compartmentation

    Read the full answer

    Joints in air and vapour control membranes must be adequately lapped, typically with a minimum overlap of 100mm, to ensure continuity of the membrane. These joints should ideally be supported by underlying structural elements like studs or noggings.

    Basis in regulation

    How to check it on site

    Check that all AVCL joints have the specified minimum lap and are properly supported where possible.

    Common failure

    Inadequate lapping or unsupported joints can create weak points in the AVCL, leading to air leakage and vapour ingress.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.