Minimum masonry thickness around a flue
100 mm around the flue; 200 mm between flues serving different dwellings
Masonry chimneys built with a suitable liner.
The masonry around a flue, excluding the liner, should be at least 100 mm thick. Where a flue passes beside a flue serving another dwelling, at least 200 mm of solid masonry should separate the two.
Basis in regulation
How to check it on site
Measure the wall thickness at the chimney breast before plastering, and check the liners are the right way up with sockets uppermost.
Common failure
Chimney cheeks built in half brick with a liner squeezed in, leaving less than 100 mm of masonry around the flue.
Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.