Minimum
    England

    Ventilation openings to a cold pitched or flat roof void

    25 mm continuous at the eaves; 5 mm at the ridge for pitches of 15° or more; 25 mm at both sides of a cold flat roof

    Cold roof construction with insulation at ceiling level

    Every figure for this topic is on one page: Roof void ventilation, access and fire compartmentation

    Read the full answer

    Continuous free-air openings needed to ventilate a cold roof void, expressed as an equivalent continuous gap.

    Basis in regulation

    How to check it on site

    Look into the void from the loft hatch before insulation is topped up. Check eaves trays are in place and insulation has not been pushed tight into the eaves.

    Common failure

    Loft insulation stuffed over the wall plate, closing the eaves gap and causing condensation on the underlay.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.