Minimum
    England

    Separation between a flue and combustible material

    200 mm from the flue face, or 40 mm from the outer face of the masonry

    Masonry chimneys and fireplace recesses serving combustion appliances.

    Combustible material should be kept at least 200 mm away from the inside surface of a flue, or at least 40 mm from the outer surface of a masonry chimney or fireplace recess.

    Basis in regulation

    How to check it on site

    Check joist trimming, floor decking and skirting runs around the chimney breast before the trimming is boarded over.

    Common failure

    Joist ends or timber grounds built hard against the chimney breast where nobody can see them once the floor is down.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.