    High-level and ceiling air permeability for ventilation

    5,000 mm

    High-level ventilation, typically 5000mm²/m, is necessary for pitched roofs where the pitch exceeds 35°

    Every figure for this topic is on one page: Roof void ventilation, access and fire compartmentation

    Read the full answer

    High-level ventilation, typically 5000mm²/m, is necessary for pitched roofs where the pitch exceeds 35°. The air permeability of the ceiling beneath a cold roof significantly influences the required ventilation, with a normal ceiling being less airtight than a well-sealed ceiling, which conforms to strict air permeability standards.

    Basis in regulation

    How to check it on site

    Check for high-level ventilation where applicable and confirm the ceiling construction aligns with the assumed air permeability for the chosen ventilation strategy.

    Common failure

    Omission of high-level ventilation on steeper roofs or assuming a well-sealed ceiling without proper construction, resulting in inadequate condensation control.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.