    Hybrid roof ventilation and AVCL

    25 mm

    Hybrid roof constructions require a minimum 25mm clear airflow path below the underlay to ensure effective ventilation

    Every figure for this topic is on one page: Roof void ventilation, access and fire compartmentation

    Read the full answer

    Hybrid roof constructions require a minimum 25mm clear airflow path below the underlay to ensure effective ventilation. When a continuous air and vapour control layer (AVCL) is not practical to install, increased high-level ventilation of 5,000mm²/m is necessary to compensate for the reduced vapour resistance.

    Basis in regulation

    How to check it on site

    Ensure a consistent 25mm clear air gap is maintained below the underlay and confirm the presence and integrity of the AVCL or compensatory increased ventilation.

    Common failure

    The 25mm air gap is often obstructed by insulation or battens, and AVCLs can be poorly taped or damaged, compromising moisture control.