Minimum
    England

    Sub-floor ventilation opening area

    1500 mm² per metre run of external wall, or 500 mm² per square metre of floor area — whichever is the greater

    Suspended ground floor with a ventilated void

    Every figure for this topic is on one page: Roof void ventilation, access and fire compartmentation

    Read the full answer

    The minimum ventilation provided to a suspended ground floor void.

    Basis in regulation

    How to check it on site

    Count and measure airbricks on every elevation, then check the ducts through the cavity are clear and not blocked by mortar droppings or insulation.

    Common failure

    Airbricks correct in number but ducted through with sleeves that are blocked, crushed or bedded solid.

    Effective from 20 August 2026. Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.