Minimum
    England

    Ventilated void depth under a suspended timber floor

    75 mm to the underside of the wall plate and 150 mm to the underside of the joists

    Suspended timber ground floor over a ventilated void

    Clear depth required between the ground surface and the timber of a suspended ground floor.

    Basis in regulation

    How to check it on site

    Measure at the deepest point of the oversite before the floor is decked. Check the void is clear of spoil, offcuts and mortar droppings that reduce the depth or block cross-flow.

    Common failure

    Oversite left high after backfill, or the void part-filled with site debris so air cannot move across it.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.