Minimum
    England

    Cavity tray upstand height

    150 mm

    Cavity tray over an opening, abutment or cavity interruption

    Every figure for this topic is on one page: Cavity trays and DPC: where are they needed and how high?

    Read the full answer

    The minimum vertical rise of a cavity tray from its bedding in the outer leaf to its termination in the inner leaf.

    Cavity tray stepped 150mm up the inner leaf with stop ends and weep holesouter leafinner leafcavity tray150 min upstandweeps
    The tray steps up the cavity to the inner leaf with sealed stop ends, discharging through weep holes in the outer leaf.Original ProPlot drawing, not to scale. Geometry verified against Approved Document C, resistance to moisture.

    Basis in regulation

    How to check it on site

    Photograph each tray before the next lift covers it. Confirm the tray rises at least 150 mm, is continuous, and has stop ends and weep holes at each end.

    Common failure

    Trays laid flat or with too little rise, missing stop ends, and weep holes omitted so water collects on the tray and tracks inwards.

    Effective from 20 August 2026. Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.