Minimum
    England

    External drainage outlet and DPC clearance

    150 mm

    External rainwater downpipes must discharge at least 150mm below the damp proof course (DPC) level, typically into a gulley or soakaway, to prevent moisture bridging across the DPC into the substructure

    Every figure for this topic is on one page: Cavity trays and DPC: where are they needed and how high?

    Read the full answer

    External rainwater downpipes must discharge at least 150mm below the damp proof course (DPC) level, typically into a gulley or soakaway, to prevent moisture bridging across the DPC into the substructure. Subfloor ventilators should not be located directly beneath door openings where they could become obstructed or allow water ingress.

    Basis in regulation

    How to check it on site

    Verify that all external drainage outlets are at least 150mm below the DPC and that no subfloor ventilators are positioned under doorways.

    Common failure

    Drainage discharges too close to or above DPC, causing damp, or ventilators are placed in vulnerable positions under door thresholds.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.