Minimum
    England

    Ground drainage pipe support

    100 mm

    Underground drainage pipes require proper support, either on a minimum 100mm deep granular bed or a carefully hand-trimmed trench bottom

    Underground drainage pipes require proper support, either on a minimum 100mm deep granular bed or a carefully hand-trimmed trench bottom. Avoid using hard, temporary supports like bricks, which create rigid points and can deform the pipe run. Pipes under suspended floors in areas of potential ground movement need additional design considerations.

    Basis in regulation

    How to check it on site

    Verify that pipes are laid on specified granular bedding or a suitably prepared trench bottom, free from hard spots.

    Common failure

    Use of inappropriate or temporary supports leading to hard spots and pipe distortion or failure.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.

    Related dimensions at this stage

    We use cookies to keep you logged in and improve ProPlot. Privacy Policy