exact
    England

    Nominal mortar joint thickness

    10 mm nominal

    Brick and block masonry laid to a gauge rod.

    Bed and perpend joints in masonry are set out on a 10 mm nominal joint. Joints should stay reasonably consistent across the elevation rather than being opened and closed to chase the gauge.

    Basis in regulation

    How to check it on site

    Check the gauge rod against the course heights at each lift; drifting joints show up badly on a long elevation.

    Common failure

    Joints opened up to pull the brickwork back onto gauge, leaving a visibly thick band of mortar across the elevation.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.