Separation of flues from combustible materials
25 mm
Flues must be adequately separated from combustible materials to prevent fire hazards, typically requiring a minimum clearance of 25mm
Flues must be adequately separated from combustible materials to prevent fire hazards, typically requiring a minimum clearance of 25mm. When flues pass through combustible elements like walls, floors, or roofs, a non-combustible sleeve is necessary, maintaining a 25mm air gap or using non-combustible insulation within that gap. This separation is measured from the outer surface of the flue wall or the inner wall of multi-walled products.
Basis in regulation
How to check it on site
Confirm minimum 25mm clearance between flue pipe outer surface and any combustible materials, and verify non-combustible sleeving where flues pass through combustible structures.
Common failure
Insufficient clearance between flue pipes and combustible timbers or plasterboard, posing a fire risk.
Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.