Maximum
    England

    Smoke alarm siting distances

    Within 7.5 m of the door to every habitable room, within 3 m of every bedroom door, and at least 300 mm from any wall or light fitting

    Ceiling-mounted mains-powered alarms on circulation routes

    Distances that govern where ceiling-mounted smoke alarms are positioned in a dwelling.

    Basis in regulation

    How to check it on site

    Mark alarm positions against the room layout at first fix, before ceilings are boarded and the cable drops are fixed.

    Common failure

    Alarm centred on the landing for appearance, leaving the far bedroom door outside the 3 m limit.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.