Minimum
    England

    Water seal depth at appliance traps

    75 mm for baths, basins, sinks and showers on a branch; 50 mm for a WC trap

    Appliance trap on a branch discharge pipe

    Depth of water seal that must be retained at each appliance trap to keep drain air out of the dwelling.

    Basis in regulation

    How to check it on site

    Test at second fix by filling and discharging each appliance, then checking the seal has not been drawn out by the run.

    Common failure

    Shallow-seal traps fitted to gain fall under a bath, so the seal siphons when an upstairs appliance discharges.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.