Minimum
England
Fire resistance of a compartment floor between flats
60 minutes
Includes the ceiling line, service voids and any penetrations through it
Every figure for this topic is on one page: Cavity barriers and fire stopping around openings and services
Read the full answerA floor separating flats is a compartment floor and must resist fire for the same period as the walls around it.
Basis in regulation
How to check it on site
Inspect above the ceiling before it is boarded — downlights, ducts and pipework all break the line.
Common failure
Downlight and extract penetrations cut in later, with no rated hoods fitted.
Effective from 22 August 2026. Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.