Maximum
    England

    Maximum pipe diameter through a compartment wall or floor

    40 mm

    Nominal internal diameter for a non-fire-rated pipe; larger pipes need a tested sleeve, collar or non-combustible material

    Every figure for this topic is on one page: Cavity barriers and fire stopping around openings and services

    Read the full answer

    Where a plastic pipe passes through a fire-separating element without a proprietary collar, its size is limited so the opening cannot become a large breach.

    Basis in regulation

    How to check it on site

    Check the pipe type and diameter at every separating wall or floor crossing, and log the collar product where one is used.

    Common failure

    Full-bore 110 mm soil pipes taken through a compartment floor with expanding foam only.

    Effective from 22 August 2026. Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.