Intermittent extract rates by room
Kitchen 30 l/s next to the hob or 60 l/s elsewhere; utility room 30 l/s; bathroom 15 l/s; WC 6 l/s
Intermittent mechanical extract in a wet room
Every figure for this topic is on one page: Roof void ventilation, access and fire compartmentation
Read the full answerMinimum intermittent extract ventilation rate for each wet room in a dwelling.
Basis in regulation
How to check it on site
Measure with an anemometer at the terminal, not the fan, and record the reading per room for the commissioning sheet.
Common failure
A fan rated at the correct rate but ducted through long flexible runs and tight bends, so the measured flow falls short.