Range
    England

    Handrail height on a stair or ramp

    900–1000 mm above the pitch line or floor

    Private stair, landing or ramp in a dwelling

    Every figure for this topic is on one page: Stair dimensions and handrail heights in UK homes

    Read the full answer

    Height range for a handrail measured vertically above the pitch line of a flight, or above the surface of a landing or ramp.

    Basis in regulation

    How to check it on site

    Check the height at the top and bottom of every flight — a bracket set out from the string can put the mid-flight height outside the range.

    Common failure

    Handrail set to the top of the newel post rather than the pitch line, so the height drifts down the flight.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.