Minimum
    England

    Breather membrane lap on a timber frame

    100 mm

    Horizontal laps shingled downwards; vertical laps over a stud, taped where the manufacturer requires it

    Every figure for this topic is on one page: Timber frame stud spacing, sheathing and restraint straps

    Read the full answer

    Membrane joints are lapped so water always runs onto the sheet below, never into the joint.

    Basis in regulation

    How to check it on site

    Check laps before the outer leaf rises past them — they are unverifiable afterwards.

    Common failure

    Upside-down laps at window heads, letting water track behind the membrane.

    Effective from 22 August 2026. Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.