Minimum
    England

    Traditional manhole construction

    100 mm

    Traditional manholes feature a concrete base at least 100mm thick and walls constructed from brick, blockwork, or concrete appropriate to ground conditions

    Traditional manholes feature a concrete base at least 100mm thick and walls constructed from brick, blockwork, or concrete appropriate to ground conditions. Wall thickness starts at 100mm for shallow, non-vehicular applications and increases to 200mm or more where ground pressure, groundwater, or traffic loads are present. Benching requires a smooth, steel-trowelled finish with rounded corners and a minimum fall of 1:12.

    Basis in regulation

    How to check it on site

    Verify base thickness, wall material and thickness relative to depth and loading, and confirm benching is smooth, rounded, and has the correct fall.

    Common failure

    Inadequate wall thickness for site conditions, or poorly finished benching which promotes debris accumulation rather than smooth flow.

    Last updated 23 August 2026. This is our editorial summary of publicly available regulation, not building control approval or a warranty determination.

    Related dimensions at this stage